Code
|
Description
|
|
A1
|
Low diesel fuel level
|
|
A11
|
Low engine oil pressure
|
|
A12
|
High coolant temperature
|
|
A13
|
High discharge pressure
|
|
A14
|
Electrical diagram
|
|
A15
|
Excessive battery voltage
|
|
A16
|
Battery Voltage Low
|
|
A17
|
High Discharge Temp.
|
|
A18
|
Low Refrigerant Pressure
|
|
A19
|
Stop - Low Fuel
|
|
A20
|
Compressor Signal Limit
|
|
A21
|
Signal reset by a specialist
|
|
A22
|
Weak suction overheating
|
|
A23
|
Network congestion
|
|
A24
|
Compression ratio
|
|
A27
|
High suction pressure
|
|
A28
|
Check refrigeration circuit
|
|
A30
|
Failure to work for a minimum period of time
|
|
A31
|
Failure to autostart
|
|
A34
|
Engine Stop Failure
|
|
A35
|
Check starter circuit
|
|
A36
|
Check coolant temperature
|
|
A37
|
Check for low engine speed
|
|
A38
|
Check high engine speeds
|
|
A39
|
Check engine speed
|
|
A40
|
Check the glow plugs
|
|
A41
|
< div>Engine stalled |
|
A51
|
No charger current
|
|
A53
|
Temperature in the body is out of tolerance
|
|
A54
|
Incomplete defrosting
|
|
A55
|
Check the defrost air relay
|
|
A57
|
Check extras. off 1
|
|
A58
|
Check extras. off 2
|
|
A59
|
No data entry
|
|
A60
|
Recording time is incorrect
|
|
A61
|
Door is open
|
|
A66
|
Check the evaporator temperature sensor
|
|
A71
|
Fuses F2 or F3 are faulty
|
|
A73
|
No power, check cable
|
|
A75
|
Compressor motor overload
|
|
A76
|
Condenser motor overheating
|
|
A77
|
Evaporator motor overheating
|
|
A89
|
Check extras. ind. automatic
|
|
A91
|
Check htcon1 coil
|
|
A92
|
Check htcon2 coil
|
|
A93
|
Check the buzzer
|
|
A94
|
Check compressor contactor
|
|
A95
|
Check condenser fan contactor
|
|
A96
|
Check Generator Contactor
|
|
A98
|
Check High Temperature Thermostat
|
|
A99
|
Check the network contactor
|
|
A100
|
Overload / Current Leakage
|
|
A109
|
Check evcon coil
|
|
A112
|
Check usv coil
|
|
A113
|
Check esv coil
|
|
A114
|
Check the liv coil
|
|
A121
|
Check the outside temperature sensor
|
|
A122
|
Check the return air sensor
|
|
A123
|
Check the air supply sensor
|
|
A124
|
Check the defrost completion temperature
|
|
A125
|
Check the discharge temperature sensor
|
|
A126
|
Check the fuel level sensor circuit
|
|
A127
|
Check the intake temperature sensor
|
|
A128
|
Current measurement
|
|
A129
|
Check the coolant temperature sensor
|
|
A130
|
Check the engine speed sensor
|
|
A131
|
Check the evaporator temperature sensor
|
|
A133
|
Check add. temp. sensor 1
|
|
A134
|
Check additional temp. sensor 2
|
|
A135
|
Check additional temp. sensor 3
|
|
P141
|
Stopping the user self-diagnosis process
|
|
P145
|
Check the speed solenoid circuit
|
|
P151
|
Check the spark plug circuit
|
|
P152
|
Check fuel solenoid circuit
|
|
P153
|
Check return air sensor
|
|
P154
|
Check the air supply sensor
|
|
P155
|
Check the coolant temperature sensor
|
|
P156
|
Check bypass valve circuit
|
|
P157
|
Check battery current
|
|
P158
|
Check the outside temperature sensor
|
|
P159
|
Check the defrost end temperature
|
|
P160
|
Check discharge temperature sensor
|
|
P161
|
Check suction temperature sensor
|
|
P169
|
Check the economizer valve circuit
|
|
P170
|
Check the injection valve circuit
|
|
P172
|
Check the bypass valve usv
|
|
P173
|
Check the economizer valve esv
|
|
P174
|
Check low engine speed
|
|
P175
|
Check high engine speed
|
|
P177
|
Check the overheating of the expansion valve
|
|
P179
|
Check the injection valve liv
|
|
P180
|
Check Suction Pressure Regulator Valve
|
|
P186
|
Check Evaporator Outlet Temperature
|
|
P187
|
Check Heater Circuit 1
|
|
P188
|
Check Heater Circuit 2
|
|
P189
|
Check evaporator fan motor
|
|
P190
|
Check condenser fan motor
|
|
P206
|
Check condenser fan circuit
|
|
P207
|
Check compressor contactor circuit
|
|
P208
|
Check the generator contactor circuit
|
|
P209
|
Check the network contactor circuit
|
|
A223
|
Engine service required
|
|
A224
|
Network service required
|
|
A225
|
General maintenance required
|
|
A226
|
Additional counter #1 maintenance required
|
|
A227
|
Needs additional counter #2
|
|
A228
|
Needs additional counter #3
|
|
A229
|
Needs additional counter #4
|
|
A230
|
Needs additional counter #5
|
|
A232
|
The specified value is invalid
|
|
A233
|
Invalid model number
|
|
A237
|
Invalid operating parameter
|
|
A238
|
Invalid configuration
|
|
A242
|
Discharge pressure calibration error
|
|
A243
|
Suction/evaporator calibration error
|
|
A245
|
Unable to save settings
|
|
A246
|
Error writing EPROM
|
|
A248
|
eprom error
|
|
A249
|
Microprocessor error
|
|
CHECK MICROPROCESSOR
|
Display / microprocessor faulty
|